Logo Department of Environment and Energy
expand_less expand_more
expand_less expand_more

Product
Electric Motors

Click the column header to sort the table.

Brand Model Available Poles Full Load Efficiency 75% Load Efficiency High Efficiency Rated Load (kW) Mounting Frame Enclosure Voltage Efficiency Standard Regulator Availability Expiry Date Registration Number more_vert
WEG 0.75kW 4P 80 W21 IE2 (Incl. W21M, Ex-db, Ex-db eb, Ex-eb, Ex-ec, Ex-tb, Ex-tc) Australia,Fiji,New Zealand 4 79.8 80.3 - 0.8 B3,B5,B6,B7,B8,B9,B10,B14,B15,B20,B25,B30,B34,B35,V1,V2,V3,V4,V5,V6,V8,V9,V10,V14,V15,V16,V18,V19,V30,V31,V36 80 IP55,IP56,IP65,IP66 220,230,240,380,400,415,440,460 Greenhouse and Energy Minimum Standards (Three Phase Electric Motors) Determination 2019 Australian Regulator Available 9 Dec 2026 AEM9432
WEG 0.75kW 4P 80 W21 IE3 (Incl. W21M, Ex-db, Ex-db eb, Ex-eb, Ex-ec, Ex-tb, Ex-tc) Australia,New Zealand 4 82.7 80.2 Yes - 2018 High Efficiency Level 0.8 B3,B5,B6,B7,B8,B9,B10,B14,B15,B20,B25,B30,B34,B35,V1,V2,V3,V4,V5,V6,V8,V9,V10,V14,V15,V16,V18,V19,V30,V31,V36 80 IP55,IP56,IP65,IP66 220,230,240,380,400 Greenhouse and Energy Minimum Standards (Three Phase Electric Motors) Determination 2019 Australian Regulator Available 10 Aug 2026 AEM9087
WEG 0.75kW 4P 80 W22 IE3 (Incl. W22M, Ex-db, Ex-db eb, Ex-eb, Ex-ec, Ex-tb, Ex-tc) Australia,Fiji,New Zealand 4 82.6 83.5 Yes - 2005 High Efficiency Level 0.8 B3,B5,B6,B7,B8,B9,B10,B14,B15,B20,B25,B30,B34,B35,V1,V2,V3,V4,V5,V6,V8,V9,V10,V14,V15,V16,V18,V19,V30,V31,V36 80 IP55,IP56,IP65,IP66 380,400,415,460,690 Greenhouse and Energy Minimum Standards (Three Phase Electric Motors) Determination 2019 Australian Regulator Available 6 May 2024 AEM7163
WEG 0.75kW 4P 90S W21 IE2 (Incl. W21M, Ex-db, Ex-db eb, Ex-eb, Ex-ec, Ex-tb, Ex-tc) Australia,Fiji,New Zealand 4 80.3 80.5 No 0.8 B3,B5,B6,B7,B8,B9,B10,B14,B15,B20,B25,B30,B34,B35,V1,V2,V3,V4,V5,V6,V8,V9,V10,V14,V15,V16,V18,V19,V30,V31,V36 90 S IP55,IP56,IP65,IP66 220,230,240,380,400,415,460 Greenhouse and Energy Minimum Standards (Three Phase Electric Motors) Determination 2019 Australian Regulator Available 6 May 2024 AEM7166
WEG 0.75kW 4P 90 W22 IE3 Australia,Fiji,New Zealand 4 84.9 85.5 Yes - 2018 High Efficiency Level 0.8 B3,B5,B6,B7,B8,B9,B10,B14,B15,B20,B25,B30,B34,B35,V1,V2,V3,V4,V5,V6,V8,V9,V10,V14,V15,V16,V18,V19,V30,V31,V36 90S IP55,IP56,IP65,IP66 200,220,230,240,380,400,415,440,460,480,550,690,1000 Greenhouse and Energy Minimum Standards (Three Phase Electric Motors) Determination 2019 Australian Regulator Available 30 Apr 2029 AEM11004
WEG 0.75kW 4P NEMA56 415V 50Hz Australia,Fiji,New Zealand 4 80.7 79.8 - 0.8 B3,B5,B6,B7,B8,B9,B10,B14,B15,B20,B25,B30,B34,B35,V1,V2,V3,V4,V5,V6,V8,V9,V10,V14,V15,V16,V18,V19,V30,V31,V36 56 IP55 415 Greenhouse and Energy Minimum Standards (Three Phase Electric Motors) Determination 2019 Australian Regulator Available 24 Apr 2028 AEM10227
TECO 0.75kW-4 pole-D80-AEHBXZ/AEUBXZ Australia,New Zealand 4 80.0 79.0 - 0.8 B3,B5,B7,B14,B34,B35,V1,V3,V5,V6,V15,V18,V19,V36 80 M (foot) IP55,IP56 220,230,240,380,400,415,440 Greenhouse and Energy Minimum Standards (Three Phase Electric Motors) Determination 2019 Australian Regulator Available 8 Dec 2025 AEM8595
TECO 0.75kW-4 pole-D80-AEMB/V Australia,New Zealand 4 84.5 82.0 Yes - 2018 High Efficiency Level 0.8 B3,B5,B6,B7,B8,B14,B34,B35,V1,V3,V5,V6,V15,V18,V19,V36 80 M (foot) IP56,IP65,IP66 220,230,240,380,400,415,440,460,480 Greenhouse and Energy Minimum Standards (Three Phase Electric Motors) Determination 2019 Australian Regulator Available 22 Oct 2025 AEM8415
TECO 0.75kW - 4 pole - D80 - AEMBXZ/AEMVXZ Australia,New Zealand 4 82.5 82.0 Yes - 2018 High Efficiency Level 0.8 B3,B5,B6,B7,B8,B14,B34,B35,V1,V3,V5,V6,V15,V18,V19,V36 80 M (foot) IP55,IP56 220,230,240,380,400,415 Greenhouse and Energy Minimum Standards (Three Phase Electric Motors) Determination 2019 Australian Regulator Available 1 Jul 2025 AEM8145
TECO 0.75kW-4 pole-D80-AESV3S-AESU3S-AEEV3N-AEUV3N Australia,New Zealand 4 82.6 82.0 Yes - 2018 High Efficiency Level 0.8 B3,B5,B14,B34,B35 80 M (foot) IP55,IP56,IP65,IP66 220,230,240,380,400,415 Greenhouse and Energy Minimum Standards (Three Phase Electric Motors) Determination 2019 Australian Regulator Available 16 Aug 2028 AEM10407
WEG 0.75kW 6P 90S/L W21 IE2 (Incl. W21M, Ex-db, Ex-db eb, Ex-eb, Ex-ec, Ex-tb, Ex-tc) Australia,Fiji,New Zealand 6 76.8 76.9 No 0.8 B3,B5,B6,B7,B8,B9,B10,B14,B15,B20,B25,B30,B34,B35,V1,V2,V3,V4,V5,V6,V8,V9,V10,V14,V15,V16,V18,V19,V30,V31,V36 90 S/L IP55,IP56,IP65,IP66 220,230,240,380,400,415,460 Greenhouse and Energy Minimum Standards (Three Phase Electric Motors) Determination 2019 Australian Regulator Available 6 May 2024 AEM7167
WEG 0.75kW 6P 90S/L W21 IE3 (Incl. W21M, Ex-db, Ex-db eb, Ex-eb, Ex-ec, Ex-tb, Ex-tc) Australia,Fiji,New Zealand 6 79.0 79.1 Yes - 2006 MEPS Level 0.8 B3,B5,B6,B7,B8,B9,B10,B14,B15,B20,B25,B30,B34,B35,V1,V2,V3,V4,V5,V6,V8,V9,V10,V14,V15,V16,V18,V19,V30,V31,V36 90 S/L IP55,IP56,IP65,IP66 220,230,240,380,400,415,460 Greenhouse and Energy Minimum Standards (Three Phase Electric Motors) Determination 2019 Australian Regulator Available 6 May 2024 AEM7168
WEG 0.75kW 6P 90 W22 IE3 Australia,Fiji,New Zealand 6 79.3 80.1 Yes - 2018 High Efficiency Level 0.8 B3,B5,B6,B7,B8,B9,B10,B14,B15,B20,B25,B30,B34,B35,V1,V2,V3,V4,V5,V6,V8,V9,V10,V14,V15,V16,V18,V19,V30,V31,V36 90S/L IP55,IP56,IP65,IP66 200,220,230,240,380,400,415,440,460,480,550,690,1000 Greenhouse and Energy Minimum Standards (Three Phase Electric Motors) Determination 2019 Australian Regulator Available 29 Apr 2029 AEM10973
TECO 0.75kW-6 pole-D90S-AEHBXZ/AEUBXZ Australia,New Zealand 6 78.0 78.0 - 0.8 B3,B5,B7,B14,B34,B35,V1,V3,V5,V6,V15,V18,V19,V36 90 S (foot) IP55,IP56 220,230,240,380,400,415,440 Greenhouse and Energy Minimum Standards (Three Phase Electric Motors) Determination 2019 Australian Regulator Available 23 Jan 2026 AEM8730
TECO 0.75kW-6 pole-D90S-AEMB/V Australia,New Zealand 6 80.5 80.0 Yes - 2018 High Efficiency Level 0.8 B3,B5,B6,B7,B8,B14,B34,B35,V1,V3,V5,V6,V15,V18,V19,V36 90 S (foot) IP56,IP65,IP66 220,230,240,380,400,415,440,460,480 Greenhouse and Energy Minimum Standards (Three Phase Electric Motors) Determination 2019 Australian Regulator Available 3 Sep 2025 AEM8317
TECO 0.75kW-6 pole-D90S-AESV3A/AESU3A Australia,New Zealand 6 78.9 80.6 Yes - 2018 High Efficiency Level 0.8 B3,B5,B35 90 S (foot) IP55,IP56,IP65,IP66 380,400,415,440,460 Greenhouse and Energy Minimum Standards (Three Phase Electric Motors) Determination 2019 Australian Regulator Available 11 Jun 2026 AEM8956
WEG 0.75kW 8P 100L W21 IE2 (Incl. W21M, Ex-db, Ex-db eb, Ex-eb, Ex-ec, Ex-tb, Ex-tc) Australia,Fiji,New Zealand 8 77.5 77.7 No 0.8 B3,B5,B6,B7,B8,B9,B10,B14,B15,B20,B25,B30,B34,B35,V1,V2,V3,V4,V5,V6,V8,V9,V10,V14,V15,V16,V18,V19,V30,V31,V36 100 L IP55,IP56,IP65,IP66 220,230,240,380,400,415,460 Greenhouse and Energy Minimum Standards (Three Phase Electric Motors) Determination 2019 Australian Regulator Available 3 May 2024 AEM7121
WEG 0.75kW 8P 100 W22 IE3 Australia,Fiji,New Zealand 8 77.2 77.4 Yes - 2018 High Efficiency Level 0.8 B3,B5,B6,B7,B8,B9,B10,B14,B15,B20,B25,B30,B34,B35,V1,V2,V3,V4,V5,V6,V8,V9,V10,V14,V15,V16,V18,V19,V30,V31,V36 100L IP55,IP56,IP65,IP66 200,220,230,240,380,400,415,440,460,480,550,690,1000 Greenhouse and Energy Minimum Standards (Three Phase Electric Motors) Determination 2019 Australian Regulator Available 30 Apr 2029 AEM11017
TECO 0.75kW-8 pole-D100L-AEMB/V Australia,New Zealand 8 76.6 76.5 Yes - 2018 High Efficiency Level 0.8 B3,B5,B6,B7,B8,B14,B34,B35,V1,V3,V5,V6,V15,V18,V19,V36 100 L (foot) IP56,IP65,IP66 220,230,240,380,400,415,440,460,480 Greenhouse and Energy Minimum Standards (Three Phase Electric Motors) Determination 2019 Australian Regulator Available 3 Sep 2025 AEM8324
TECO 0.75kW-8 pole-D100L-AESV3A/AESU3A Australia,New Zealand 8 75.0 74.7 Yes - 2018 High Efficiency Level 0.8 B3,B5,B35 100 L (foot) IP55,IP56,IP65,IP66 380,400,415,440,460 Greenhouse and Energy Minimum Standards (Three Phase Electric Motors) Determination 2019 Australian Regulator Available 9 Jul 2026 AEM9008
  • [*] "N/A" results are from models registered under the old Determination/Regulation, yet comply with the new Determination/Regulation's Minimum Energy Performance Standard